Campbell Scientific · Data logger
CR1000Xe – Campbell Scientific data logger
Certified Campbell Scientific partnerThe CR1000Xe is Campbell Scientific’s all-round logger and the successor to the CR1000X. It suits most weather and water stations and larger measurement systems, and programs written for the CR1000X run the same way on the new logger.
Suited to
Weather stations
Temperature, humidity, wind, precipitation, radiation and visibility in one station.
Water level and flow
Pressure transducers and radar, flow calculation and alarms at high levels.
Masts and research
Many sensors and calculations in the logger itself.
Control and alarms
The logger can switch, for example, heaters, cameras and modems on and off based on the readings.
Key data
| CR1000Xe | |
|---|---|
| Analog inputs | 16 single-ended or 8 differential, two of which accept 4–20 mA directly |
| Pulse counters | 10 |
| Digital terminals | 8 C terminals, all with RS-232 or RS-485 |
| Communication | USB-C, Ethernet, RS-232, RS-485/422, CS I/O and CPI |
| Protocols | Including SDI-12, Modbus, DNP3 and MQTT |
| Power | 10–36 V DC, works in 12 V and 24 V systems |
| Operating temperature | −40 to +70 °C, extended −55 to +85 °C |
| Memory | 4 MB SRAM and 72 MB flash, microSD card up to 16 GB |
| Wireless | Cellular, Wi-Fi or satellite through an external device |
Full specifications, datasheet and manual are available from Campbell Scientific ↗.
From the CR1000X and CR1000
The CR1000Xe replaces the CR1000X, which can no longer be ordered. According to Campbell Scientific, programs written for the CR1000X run the same way on the CR1000Xe. New features include USB-C, a supply of up to 36 V, a stronger switched 12 V output (SW12) and serial communication on all C terminals.
For the older CR1000, Campbell Scientific recommends the CR1000X family, which today means the CR1000Xe. The program needs adapting when you switch, and we help with that.
What we do
Choice and quote
We help you choose accessories, modem and power supply and send you a quote.
Programming
CRBasic programs with calculations, alarms and control, tested before delivery.
Installation
Mounting, sensor wiring and commissioning on site.
Service
Troubleshooting, updates, spare parts and service agreements.
Frequently asked questions about the CR1000Xe
Can we use our CR1000X program?
Yes. According to Campbell Scientific, programs written for the CR1000X run the same way on the CR1000Xe.
Can the CR1000X still be ordered?
No. Campbell Scientific recommends the CR1000Xe instead.
Does the CR1000Xe handle 24 V?
Yes. It takes a 10 to 36 V DC supply and works in both 12 V and 24 V systems.
How is the logger connected to the mobile network?
Through an external cellular modem. We choose the modem and antenna for the site.
More data loggers and services
Would you like a quote for a CR1000Xe?
Tell us what the station will measure, and we will suggest logger, accessories and communication.