Skip to content
EN · SV

Gill Instruments · Weather stations

MaxiMet from Gill Instruments

Distributor for Gill Instruments in Sweden

MaxiMet is Gill Instruments’ range of compact weather stations. A single unit measures wind ultrasonically and, depending on model, temperature, humidity, pressure, solar radiation and precipitation. It mounts on a pipe, connects with one cable and delivers finished values via SDI-12, Modbus or NMEA.

The models

The model number tells you what the station measures. These are the ones we suggest most often.

  • Wind

    MaxiMet GMX200

    Wind speed and direction, with a built-in compass.

    • 0–60 m/s, 0.5 kg.
    • The GMX240 also measures rainfall optically.
  • Wind and weather

    MaxiMet GMX500

    Wind, temperature, humidity and pressure. According to Gill, the most specified model.

    • Temperature ±0.3 °C, humidity typically ±2%.
    • Optional heating.
  • With solar radiation

    MaxiMet GMX501

    As the GMX500, with a built-in pyranometer for 0–1600 W/m².

    • The GMX551 also has an input for a rain gauge.
  • With rain gauge input

    MaxiMet GMX550

    As the GMX500, with an input for an external rain gauge.

    • Suits tipping bucket gauges and Gill’s optical TruMet PW100.
  • With optical rainfall

    MaxiMet GMX603

    As the GMX500, with built-in optical measurement of rain, 0–200 mm/h.

    • Resolution 0.1 mm.
    • Accuracy 5% or better.
  • Marine

    MaxiMet GMX560

    For ships, buoys and platforms, with a compass that also measures pitch and roll.

    • Sealed to IP66 and IP68.
    • The GMX260 is the corresponding wind-only model.

New in the range is the GMX552, which uses a black globe to calculate the heat stress index WBGT for outdoor workplaces.

Compare the models

What each model measures.

GMX200GMX500GMX501GMX551GMX603
WindYesYesYesYesYes
Temperature, humidity and pressure–YesYesYesYes
Solar radiation––YesYes–
Precipitation–––Input for an external gaugeBuilt-in optical measurement
HeatingNoOptionalOptionalOptionalOptional
Weight0.5 kg0.7 kg0.8 kg0.8 kg1.1 kg

Swipe sideways to see the whole table. Simplified figures. Full specifications and datasheets are available from Gill Instruments ↗.

What the MaxiMet models have in common

Wind is measured ultrasonically over 0–60 m/s. A built-in compass is used to correct the wind direction, and GPS is available as an option. Besides the measured values the sensor calculates dew point, WMO average and gust wind and pressure at sea level, among other things.

The GMX500 draws 26 mA at 12 V, and 1.3 mA in eco-power mode with one reading per hour. The MetSet and MetView programs, for set-up and display, are free.

  • Wind0–60 m/s, direction ±3°
  • Temperature±0.3 °C
  • Humidity0–100%, typically ±2%
  • Pressure300–1250 hPa
  • Operating temperature−35 to +70 °C, −40 °C with heating
  • ProtectionIP66

More weather stations and precipitation

When the station has to be extended or precipitation measured separately.

  • Modular weather station

    MetConnect One

    A stainless steel hub box with a WindSonic, temperature, humidity and pressure.

    • Inputs for Pt100, two analogue sensors and a rain gauge.
    • SDI-12, Modbus, NMEA and ASCII.
  • Modular weather station

    MetConnect THP

    As the MetConnect One but without a built-in wind sensor, with an input for a separate Gill wind sensor.

    • Can be combined with a heated wind sensor.
  • Precipitation

    TruMet PW100

    An optical rain gauge with no moving parts, for rain up to 200 mm/h.

    • One pulse per 0.1 mm, like a tipping bucket.
    • Connects to the MaxiMet GMX550 and GMX551.

What we do

  • Choice and quote

    We help you choose model, output, heating and cable and send you a quote.

  • Wiring

    The sensor is connected to a Campbell Scientific data logger or directly to your system.

  • Installation

    Mounting, alignment and commissioning on site, on a mast, roof or quay.

  • Service

    Troubleshooting, checks and spare parts, and help when a sensor has to go back to Gill.

Frequently asked questions about MaxiMet

MaxiMet or separate sensors?

MaxiMet is quick to install and easy to replace. Separate sensors on a mast give more freedom to choose measurement heights, accuracy and heating. We help you weigh one against the other.

Can MaxiMet be connected to a data logger?

Yes. With SDI-12 it connects directly to a Campbell Scientific data logger, which stores the values and sends them on.

Does MaxiMet cope with winter?

The sensor operates down to −35 °C. The GMX500, GMX501, GMX550, GMX551, GMX560 and GMX603 are available with heating of the wind transducers and then operate down to −40 °C.

Does MaxiMet measure snow?

No. The optical precipitation measurement in the GMX603 measures rain. For snow depth and winter precipitation we suggest separate sensors.

Would you like a quote for a MaxiMet?

Tell us what the station will measure and what it will connect to, and we will suggest a model.